Fraser-Johnston Runaway Cooling / Stuck Contactor or Control Fault

Outdoor unit runs continuously and will not shut off

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Stuck closed contactor, Shorted thermostat wiring calling for constant cooling, Faulty control board output, Thermostat set too low or malfunctioning

How to Fix / Troubleshooting

Safety: Turn off power at the outdoor disconnect immediately to prevent damage.

  • Inspect contactor: With power off, check if the contactor contacts are welded closed. Replace if they do not open freely.
  • Check thermostat: Raise the thermostat setpoint above room temperature. If the outdoor unit still runs when power is restored, suspect wiring or control issues.
  • Inspect low-voltage wiring: Look for shorts between Y and R in the thermostat cable or at the air handler board.
  • Control board: If the board is sending 24 VAC to the contactor when there is no call for cooling, replace the board.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Contactor
Check Price on Amazon