Friedrich Condenser Fan Failure

Outdoor fan does not run but compressor is operating

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed condenser fan motor, seized fan blade, loose wiring, defective outdoor PCB fan driver

How to Fix / Troubleshooting

Safety: Turn OFF power at the breaker before working on the outdoor section.

Steps:

  • Inspect fan blade: Check for obstructions or damage preventing rotation. Clear debris and ensure the blade spins freely by hand.
  • Check wiring: Verify the fan motor wiring harness is connected securely to the outdoor PCB.
  • Motor test: A technician can test for proper voltage at the motor leads when the compressor is running. If voltage is present but the motor does not run, replace the condenser fan motor.
  • PCB issue: If no voltage is present and wiring is intact, the outdoor PCB may be defective.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Condenser Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.