Possible Causes
Failed condenser fan motor, seized fan blade, loose wiring, defective outdoor PCB fan driver
How to Fix / Troubleshooting
Safety: Turn OFF power at the breaker before working on the outdoor section.
Steps:
- Inspect fan blade: Check for obstructions or damage preventing rotation. Clear debris and ensure the blade spins freely by hand.
- Check wiring: Verify the fan motor wiring harness is connected securely to the outdoor PCB.
- Motor test: A technician can test for proper voltage at the motor leads when the compressor is running. If voltage is present but the motor does not run, replace the condenser fan motor.
- PCB issue: If no voltage is present and wiring is intact, the outdoor PCB may be defective.