Friedrich Short Cycling / Control or Sizing Issue

Unit short cycles (turns on and off frequently) without reaching set temperature

Advertisements

Possible Causes

Oversized unit for room, thermostat sensor located too close to supply air, dirty filter causing temperature swings, control board logic fault

How to Fix / Troubleshooting

Safety: Unplug the unit before moving sensors or covers.

Steps:

  • Clean filter and coils: Ensure proper airflow to reduce rapid temperature swings at the sensor.
  • Check sensor location: If the ambient sensor is directly in the cold air stream, reposition it slightly into the return air path as originally designed.
  • Verify mode and fan settings: Use AUTO fan mode if available to reduce rapid cycling.
  • Room sizing: If the unit is significantly oversized, consider using a lower fan speed or a smaller-capacity unit to reduce cycling.
  • Control issues: Persistent short cycling with correct sizing and sensor placement may indicate a control board problem.