F1
Frigidaire Indoor Ambient Temperature Sensor Error

Portable or window Frigidaire AC displays F1 and may not cool properly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed ambient thermistor, loose sensor connector, damaged harness, faulty main control board

How to Fix / Troubleshooting

Safety: Disconnect power before accessing internal components.

Steps:

  • 1. Power reset: Unplug for 5 minutes and restart. If F1 reappears, continue.
  • 2. Locate ambient sensor: On many portable units, the ambient sensor is near the air intake grille inside the cabinet. Remove the front cover to access it.
  • 3. Inspect wiring: Check the sensor leads for damage and ensure the connector is fully seated on the control board.
  • 4. Test sensor: Measure resistance at room temperature and compare to spec. Replace if open, shorted, or out of range.
  • 5. Replace control board: If a new sensor does not clear F1, the main PCB may be defective and require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Ambient Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.