HI
Frigidaire
High Room Temperature Indication / Sensor or Load Issue
Display shows HI and the unit may run continuously or struggle to reach set temperature.
Advertisements
Possible Causes
Room temperature above design range, undersized unit for room, failed room thermistor reading too high, poor insulation or open windows
How to Fix / Troubleshooting
Safety: Unplug the unit before accessing internal components.
Steps:
- 1. Verify actual temperature: Use a separate thermometer. If the room is genuinely very hot, improve shading, close blinds, and reduce heat sources.
- 2. Check capacity: Confirm that the BTU rating of the Frigidaire unit matches the room size. An undersized unit will show HI frequently.
- 3. Inspect room sensor: Access and test the room thermistor. Replace if readings are inaccurate.
- 4. Clean filters and coils: Dirty coils reduce capacity and can cause the unit to run continuously without cooling effectively.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Room Temperature Sensor (Thermistor)
Check Price on Amazon