HI
Frigidaire High Room Temperature Indication / Sensor or Load Issue

Display shows HI and the unit may run continuously or struggle to reach set temperature.

Advertisements

Possible Causes

Room temperature above design range, undersized unit for room, failed room thermistor reading too high, poor insulation or open windows

How to Fix / Troubleshooting

Safety: Unplug the unit before accessing internal components.

Steps:

  • 1. Verify actual temperature: Use a separate thermometer. If the room is genuinely very hot, improve shading, close blinds, and reduce heat sources.
  • 2. Check capacity: Confirm that the BTU rating of the Frigidaire unit matches the room size. An undersized unit will show HI frequently.
  • 3. Inspect room sensor: Access and test the room thermistor. Replace if readings are inaccurate.
  • 4. Clean filters and coils: Dirty coils reduce capacity and can cause the unit to run continuously without cooling effectively.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Room Temperature Sensor (Thermistor)