LO
Frigidaire
Low Temperature Protection / Display Indication
Display shows LO and the unit may not cool or may cycle oddly; temperature setting cannot be raised above a certain point.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Room temperature below operating range, faulty room thermistor reading too low, control board calibration error
How to Fix / Troubleshooting
Safety: If you need to open the unit, unplug it first.
Steps:
- 1. Check room temperature: Use a separate thermometer to verify actual room temperature. If the room is very cool, the unit may be operating normally.
- 2. Power reset: Unplug for 5 minutes and restart. If LO persists and the room is not cold, continue.
- 3. Inspect room sensor: Access the control area and locate the room thermistor. Ensure it is not touching the cold evaporator coil, which can cause false low readings.
- 4. Test and replace sensor: Measure resistance and compare to spec. Replace the room thermistor if readings are incorrect.
- 5. Control board: If the sensor is good but LO remains with incorrect temperature readings, the main control board may need replacement.