Mode Reversal / Reversing Valve or Control Fault (heat pump models)
Unit blows warm air in cooling mode or cold air in heating mode (for heat pump models) intermittently.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck reversing valve, faulty reversing valve coil, incorrect mode signal from control board, low refrigerant
How to Fix / Troubleshooting
Safety: Unplug the unit before accessing internal components. Reversing valve service involves refrigerant and should be done by a licensed technician.
Steps:
- 1. Confirm mode: Verify that the unit is set to the correct mode (Cool vs. Heat) and that the display matches your selection.
- 2. Listen for valve shift: When switching between heating and cooling, you should hear a distinct whoosh or click from the reversing valve area. If not, the valve may be stuck or not energized.
- 3. Check coil voltage (technician-level): With power on and in the correct mode, a technician can check for 24V or control voltage at the reversing valve coil. Replace the coil if it is open or not energizing.
- 4. Valve or refrigerant issues: If the coil is good but the valve does not shift, or if performance is poor in both modes, a refrigerant or valve problem exists and requires professional service.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Reversing Valve Coil
Check Price on Amazon