F3
GE
Outdoor / Condenser Sensor Out of Range
GE air conditioner displays F3 and may not regulate temperature correctly
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed outdoor thermistor, Sensor wiring open or shorted, Connector corrosion, Defective main control board
How to Fix / Troubleshooting
Safety: Unplug the unit and remove it from the window or sleeve if necessary.
Steps:
- Remove cabinet: Take off the outer shell to access the condenser coil and compressor area.
- Locate outdoor sensor: Find the thermistor attached to the condenser coil or near the compressor.
- Inspect and secure: Ensure it is properly attached and wiring is intact.
- Test sensor: Measure resistance and compare to GE specs. Replace if out of range.
- Check board: If sensor is good and wiring is intact, replace the main control board.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Outdoor Temperature Sensor (Condenser Thermistor)
Check Price on Amazon
We may earn a commission from links on this page.