GE
Restricted Airflow / Blower Problem
GE air conditioner runs but airflow from the front grille is very weak
Advertisements
Possible Causes
Clogged air filter, Evaporator coil heavily iced or dirty, Blower wheel clogged with dust, Blower wheel loose on motor shaft
How to Fix / Troubleshooting
Safety: Unplug the unit.
Steps:
- Clean filter: Remove and wash the filter.
- Check for ice: Remove front cover and inspect the evaporator coil. If iced over, turn the unit off and let it thaw completely. Then run on FAN ONLY for 30 minutes.
- Clean coil and blower: Gently clean dust from the evaporator fins and blower wheel using a soft brush and vacuum.
- Check blower attachment: Ensure the blower wheel is firmly attached to the motor shaft and not slipping. Tighten the set screw if loose.
- Fan speed: Confirm the fan speed setting is on HIGH for maximum airflow.
Advertisements
Repair Difficulty
Easy
2/5
Advertisements