F5
Gree Outdoor Unit Overload / IPM Overheat Protection

Unit shows F5; may limit operation or cause shutdown, especially in heating mode.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Outdoor heat sink or electronics compartment clogged with dust, Outdoor fan not providing enough cooling airflow, Inverter IPM module overheating, High ambient temperature combined with poor ventilation

How to Fix / Troubleshooting

Safety first: Disconnect power before opening the outdoor electrical compartment. Capacitors and inverter modules can retain charge.

  • Step 1 – Clean outdoor unit: Remove debris from the coil and ensure the fan guard is not blocked. Clean louvers and vents around the electronics compartment.
  • Step 2 – Check outdoor fan operation: After restoring power, run the unit and confirm the fan runs at appropriate speed. If it runs slowly or intermittently, the fan motor or control may be faulty.
  • Step 3 – Improve ventilation: Ensure the outdoor unit has adequate clearance and is not installed in a confined space without airflow.
  • Step 4 – Technician service: If F5 persists, a technician should inspect the outdoor PCB, IPM module, and temperature sensors, and may need to replace the outdoor control board.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Outdoor Inverter PCB
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements