F5
Gree
Outdoor Unit Overload / IPM Overheat Protection
Unit shows F5; may limit operation or cause shutdown, especially in heating mode.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Outdoor heat sink or electronics compartment clogged with dust, Outdoor fan not providing enough cooling airflow, Inverter IPM module overheating, High ambient temperature combined with poor ventilation
How to Fix / Troubleshooting
Safety first: Disconnect power before opening the outdoor electrical compartment. Capacitors and inverter modules can retain charge.
- Step 1 – Clean outdoor unit: Remove debris from the coil and ensure the fan guard is not blocked. Clean louvers and vents around the electronics compartment.
- Step 2 – Check outdoor fan operation: After restoring power, run the unit and confirm the fan runs at appropriate speed. If it runs slowly or intermittently, the fan motor or control may be faulty.
- Step 3 – Improve ventilation: Ensure the outdoor unit has adequate clearance and is not installed in a confined space without airflow.
- Step 4 – Technician service: If F5 persists, a technician should inspect the outdoor PCB, IPM module, and temperature sensors, and may need to replace the outdoor control board.