F9
Gree
Defrost Sensor or Logic Fault
Display shows F9; unit may not defrost properly or may shut down in heating mode.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Incorrect reading from outdoor coil sensor, Faulty defrost control on outdoor PCB, Sensor not properly attached to coil, Software/firmware issue on control board
How to Fix / Troubleshooting
Safety first: Turn OFF power before opening the outdoor unit.
- Step 1 – Check outdoor coil sensor placement: Ensure the sensor is firmly attached to the coil where specified by Gree and not hanging loose.
- Step 2 – Inspect wiring: Look for damaged or loose sensor wires leading to the outdoor PCB.
- Step 3 – Power reset: Turn OFF the breaker for 10 minutes to reset the control logic, then test in HEAT mode.
- Step 4 – Technician service: If F9 continues, a technician should test sensor resistance and defrost control operation, and may need to replace the outdoor PCB.