Gree
Biological Growth on Evaporator Coil and Drain Pan
Unpleasant musty or moldy smell from indoor unit when it starts.
Advertisements
Possible Causes
Dirty filters, Long periods of inactivity in humid conditions, Standing water in drain pan, Contaminated evaporator coil
How to Fix / Troubleshooting
Safety first: Turn OFF power before cleaning. Use only non‑corrosive coil cleaners approved for aluminum coils.
- Step 1 – Clean filters: Wash filters with mild detergent and dry completely.
- Step 2 – Clean evaporator coil: Remove the front panel and apply a no‑rinse foaming coil cleaner to the evaporator fins following product instructions.
- Step 3 – Clean drain pan: Wipe the drain pan with a cloth and a mixture of water and mild disinfectant to remove slime and odor.
- Step 4 – Use self‑clean function (if available): Many Gree units have a self‑clean or X‑FAN mode that dries the coil after use. Enable this feature to reduce future odors.
- Step 5 – Persistent odor: If smells persist, professional deep cleaning of the indoor unit may be required.
Advertisements
Repair Difficulty
Easy
2/5
Advertisements