F3
Haier
Outdoor Ambient Temperature Sensor Fault
Indoor unit shows F3 and may stop heating or cooling; outdoor unit may not start.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Open or shorted outdoor ambient NTC sensor, Sensor dislodged from mounting point, Corroded sensor connector on outdoor PCB
How to Fix / Troubleshooting
Safety first: Turn off power at the outdoor disconnect or breaker.
- Locate sensor: The outdoor ambient sensor is typically mounted near the air intake grille of the outdoor unit, often clipped to the coil guard or frame.
- Inspect sensor and wiring: Check for physical damage, UV-brittled insulation, or rodent-chewed wires. Repair or replace as needed.
- Check PCB connection: Open the outdoor control box and ensure the sensor connector is firmly seated on the PCB.
- Replace sensor: If readings are obviously wrong (e.g., unit thinks it is extremely hot or cold) or F3 persists, replace the sensor with a Haier-compatible outdoor ambient sensor.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Outdoor Ambient Temperature Sensor
Check Price on Amazon