H1
Haier Defrosting / Preheating Indication (Not Always a Fault)

Display shows H1 and the unit does not blow warm air in heating mode; outdoor unit may frost up.

Advertisements

Possible Causes

Normal defrost cycle in heating mode, Outdoor coil heavily frosted, Low outdoor ambient temperature, Defrost sensor or logic issue if H1 persists too long

How to Fix / Troubleshooting

Safety first: No immediate danger; H1 often indicates normal defrost. Do not force the unit to run continuously in heavy frost.

  • Observe duration: H1 should clear within several minutes once defrost completes. Warm air will resume afterward.
  • Check outdoor coil: Inspect the outdoor unit for excessive ice buildup. Clear snow and ensure drainage is not blocked.
  • Improve installation conditions: Ensure the outdoor unit has good airflow and is not installed in a location where meltwater refreezes on the coil.
  • If H1 stays on and no heating: The defrost sensor or control may be faulty. A technician should test the defrost temperature sensor and outdoor PCB.
Advertisements

Repair Difficulty

Easy 2/5