H3
Haier Compressor Overload Protection / Overheat

Indoor unit displays H3 and the compressor stops; unit will not cool or heat.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked condenser coil, Outdoor fan failure, Low or high refrigerant charge, Compressor internal fault

How to Fix / Troubleshooting

Safety first: Turn off power and allow the outdoor unit to cool before inspection.

  • Clean outdoor coil: Remove debris and wash the condenser fins with low-pressure water.
  • Check outdoor fan: Verify the fan runs at full speed when the unit is operating. Replace the fan motor if it does not start or is very slow.
  • Check ambient conditions: In very high outdoor temperatures, reduce load by closing curtains and doors to help the system.
  • If H3 recurs quickly: A technician should check compressor current, winding resistance, and refrigerant charge. Compressor or PCB replacement may be required.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Compressor
Check Price on Amazon

We may earn a commission from links on this page.