P0
Haier DC Bus Voltage Protection / Inverter Power Supply Fault

Indoor unit shows P0 and the compressor does not start or stops quickly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Low or high AC supply voltage, Faulty PFC circuit on outdoor PCB, Loose power terminals, Failing DC bus capacitors

How to Fix / Troubleshooting

Safety first: Turn off power and do not touch inverter components without proper training.

  • Check supply voltage: Have a qualified person measure line voltage at the outdoor unit. Correct any supply issues (loose breakers, undersized wiring).
  • Inspect terminals: Tighten all main power terminals in the outdoor unit.
  • Visual PCB check: Look for bulged capacitors or burnt components on the inverter board.
  • Professional repair: P0 usually requires PCB-level repair or replacement by a technician.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Outdoor Inverter PCB
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements