Haier
No Power / Main Supply Failure
Unit does not power on at all; no lights or display on indoor unit.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Tripped circuit breaker, Blown internal fuse on indoor PCB, Loose power wiring at indoor terminal block, Faulty indoor main control board
How to Fix / Troubleshooting
Safety first: Before opening any covers, switch off the breaker and verify power is off.
- Check breaker: Inspect the dedicated AC breaker in the panel. Reset if tripped; if it trips again immediately, do not force it—call an electrician or technician.
- Verify outlet (portable/window): Plug another appliance into the same outlet to confirm power is present.
- Inspect indoor terminal block: Remove the indoor unit cover and check that L and N wires are firmly secured and not burnt.
- Check PCB fuse: Many Haier indoor PCBs have a small glass or cartridge fuse. Replace only with the same rating if blown. If it blows again, there is a deeper fault.
- If still dead: The indoor PCB may be defective and require replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Indoor Main Control PCB
Check Price on Amazon