E4
Heil
Compressor Overheat / Discharge Temperature High
Heil air conditioner shuts down on very hot days; diagnostic indicates discharge temperature or compressor overheat fault
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Dirty condenser coil, Failing condenser fan motor, Overcharged refrigerant, Non-condensables in system, Restricted TXV or liquid line filter-drier
How to Fix / Troubleshooting
Safety first: Disconnect power at the outdoor disconnect before removing panels. Compressor and refrigerant diagnostics should be done by a licensed technician.
- Step 1 – Clean condenser coil: As with high-pressure faults, remove debris and wash the coil from inside out with a garden hose. Allow the unit to dry before restoring power.
- Step 2 – Verify fan operation: Restore power and observe the condenser fan. If it fails to start or is slow/noisy, shut power off and test/replace the fan motor and capacitor.
- Step 3 – Shade and airflow: Ensure the unit is not recirculating its own hot discharge air (e.g., under decks or in corners). Improve airflow or shading if possible.
- Step 4 – Professional diagnosis: If E4 persists after cleaning and verifying fan operation, a technician must check superheat/subcooling, verify charge, and inspect for restrictions or non-condensables.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Condenser Fan Motor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements