E5
Heil
Outdoor Unit Not Responding / Control Board Fault
Heil communicating thermostat shows E5; outdoor unit does not respond to cooling calls
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
No high-voltage power to outdoor unit, Blown low-voltage fuse on indoor control board, Failed outdoor control board, Miswired or shorted low-voltage wiring
How to Fix / Troubleshooting
Safety first: Turn off power at the outdoor disconnect and indoor breaker. Use a multimeter only if you are comfortable and trained to do so.
- Step 1 – Check outdoor disconnect: Verify the pull-out or breaker at the Heil condenser is fully inserted and not tripped. Reset if necessary.
- Step 2 – Inspect indoor 3–5A low-voltage fuse: On the indoor control board, locate the small automotive-style fuse. If blown, replace with the same rating. If it blows again, there is a short in the thermostat or outdoor wiring.
- Step 3 – Inspect thermostat cable: Look for damaged insulation, staples through the cable, or corrosion at wire nuts and terminals between indoor and outdoor units.
- Step 4 – Check outdoor board LEDs: With power restored, observe the outdoor control board status LED. No lights usually indicate no power or a failed board. Refer to the Heil service label for LED code meanings.
- Step 5 – Replace outdoor board if needed: If correct power and wiring are present but the board is unresponsive, replacement of the outdoor control board is typically required by a technician.