F3
Heil
Thermostat Sensor / Internal Fault
Heil thermostat shows F3; system cycles erratically or not at all
Advertisements
Possible Causes
Failed internal temperature sensor in communicating thermostat, Thermostat firmware issue, Incorrect thermostat configuration for Heil system
How to Fix / Troubleshooting
Safety first: Low-voltage only at the thermostat, but turn off power to the system at the breaker before removing thermostat to avoid shorts.
- Step 1 – Reboot thermostat: Remove the thermostat from its wall plate for 30 seconds, then reinstall. Some models also have a reset option in the menu.
- Step 2 – Check location: Ensure the thermostat is not in direct sunlight, near supply vents, or heat sources that can skew readings.
- Step 3 – Verify wiring: Confirm R, C, Y1, Y2, G, W, and communication terminals are correctly wired per Heil installation instructions.
- Step 4 – Factory reset: Use the thermostat menu to perform a factory reset and reconfigure for your specific Heil air conditioner and indoor unit.
- Step 5 – Replace thermostat: If F3 persists, the thermostat’s internal sensor or electronics are likely defective and should be replaced with a compatible Heil communicating thermostat.