HPS
Heil High-Pressure Switch Open

Heil outdoor unit LED indicates HPS; unit shuts down shortly after starting

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Dirty condenser coil, Blocked condenser airflow, Failed condenser fan motor, Overcharged refrigerant

How to Fix / Troubleshooting

Safety first: Disconnect power at the outdoor disconnect before servicing. High-pressure conditions can be dangerous.

  • Step 1 – Clean coil and clear area: Remove debris and wash the condenser coil from inside out with a garden hose.
  • Step 2 – Verify fan operation: Restore power and observe the fan. If not running, shut power off and test/replace the fan motor and capacitor.
  • Step 3 – Reset switch: Some Heil units have a manual reset high-pressure switch; press the reset button with power off.
  • Step 4 – Technician check: If HPS trips again, a professional must verify refrigerant charge and system pressures.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

High-Pressure Switch
Check Price on Amazon