OF
Heil System Off / Lockout or Safety Open

Heil thermostat or display shows OF or OFF and outdoor unit does not run

Advertisements

Possible Causes

Open float switch in condensate line, Open door switch on air handler, Tripped high- or low-pressure switch, Thermostat set to OFF

How to Fix / Troubleshooting

Safety first: Turn off power before accessing the air handler or condensate system.

  • Step 1 – Verify thermostat mode: Ensure the thermostat is set to COOL and not OFF.
  • Step 2 – Check air handler door: Confirm the blower compartment door is fully closed and engaging the safety switch.
  • Step 3 – Inspect condensate float switch: Locate the float switch on the drain pan or drain line. If the pan is full of water, clear the drain line with a wet/dry vacuum at the outside termination and flush with water.
  • Step 4 – Reset system: After clearing water and ensuring doors are closed, power cycle the system and test cooling.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Condensate Float Switch
Check Price on Amazon

We may earn a commission from links on this page.