Heil
Incorrect Replacement Fan Motor Wiring
Heil air conditioner outdoor unit fan runs backwards or at incorrect speed after motor replacement
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Miswired aftermarket fan motor, Incorrect capacitor connection, Wrong rotation motor installed
How to Fix / Troubleshooting
Safety first: Turn off power at the disconnect before touching any wiring.
- Step 1 – Verify motor model: Ensure the replacement motor matches Heil specifications for HP, RPM, voltage, and rotation.
- Step 2 – Check wiring diagram: Follow the wiring diagram on the motor and Heil unit. Confirm correct connections to C, FAN, and line.
- Step 3 – Correct rotation: Some motors have reversible rotation via a plug or wire swap; set to blow air upward out of the unit.
- Step 4 – Test operation: Restore power and verify correct direction and speed.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Condenser Fan Motor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements