Heil Intermittent Fan Operation

Heil air conditioner outdoor unit fan starts then stops after a few seconds

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Weak fan capacitor, Overheating fan motor, Loose fan motor wiring, Failing outdoor control board

How to Fix / Troubleshooting

Safety first: Turn off power at the disconnect before testing or replacing components.

  • Step 1 – Test capacitor: Check the dual run capacitor value for the FAN section and replace if weak.
  • Step 2 – Check motor temperature: After brief operation, carefully feel the motor housing (power off). If extremely hot, the motor is likely failing.
  • Step 3 – Inspect wiring: Ensure all fan motor wires are secure at the capacitor and control board.
  • Step 4 – Replace motor if needed: Install a Heil-compatible condenser fan motor if overheating or stalling persists.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Condenser Fan Motor
Check Price on Amazon