Heil
Indoor Blower Failure
Heil outdoor unit runs but indoor blower does not; coil may freeze and little or no air comes from vents
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed ECM blower motor, Blown indoor control board fuse, Faulty blower relay on control board, Seized blower wheel
How to Fix / Troubleshooting
Safety first: Turn off power to the furnace/air handler at the breaker. Blower compartments may have sharp edges.
- Step 1 – Check thermostat fan setting: Set fan to ON. If blower still does not run, proceed.
- Step 2 – Inspect fuse: Check the low-voltage fuse on the indoor control board and replace if blown. If it blows again, there is a wiring short.
- Step 3 – Inspect blower wheel: Remove blower compartment door and check if the wheel spins freely by hand. If seized or noisy, the motor bearings may be bad.
- Step 4 – Check motor connections: Ensure the ECM motor plug is fully seated. If the motor is getting power but not running, it likely needs replacement.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
ECM Blower Motor
Check Price on Amazon