E5
Hisense Overcurrent Protection / Compressor Overload

Indoor unit displays E5 and the system does not start or stops shortly after starting.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted or seized compressor, Faulty inverter module on outdoor PCB, Incorrect supply voltage or loose power connections, Short circuit in outdoor fan motor or wiring

How to Fix / Troubleshooting

Safety first: This fault involves high current and high voltage. Turn off power at the breaker and do not repeatedly reset if the breaker trips.

  • Step 1 – Check supply voltage and connections:
    • Verify that the breaker size matches the unit rating.
    • Inspect the power cable and terminal block at the outdoor unit for burnt or loose connections.
  • Step 2 – Listen for compressor behavior:
    • When power is restored and the unit is started, listen at the outdoor unit.
    • A loud humming with no start, or immediate trip, suggests compressor or inverter issues.
  • Step 3 – Inspect outdoor PCB visually:
    • With power off, remove the cover and look for burnt components, cracked solder joints, or blown fuses on the inverter board.
  • Step 4 – Call a technician:
    • Testing compressor windings, inverter module, and current draw requires specialized tools.
    • Do not attempt to bypass safety devices or run the unit with covers removed.