F5
Hisense Outdoor Unit Overload / High Ambient Protection

Indoor unit displays F5 and the unit may not cool effectively, especially in high ambient temperatures.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked outdoor airflow, Extremely high outdoor temperature, Dirty condenser coil, Outdoor fan not running at full speed

How to Fix / Troubleshooting

Safety first: Turn off power before cleaning the outdoor unit.

  • Step 1 – Clear surroundings:
    • Ensure at least 30–50 cm clearance around the outdoor unit on all sides and above.
    • Remove plants, storage items, or covers that restrict airflow.
  • Step 2 – Clean condenser coil:
    • Use a soft brush or low-pressure water to remove dust and dirt from the fins.
    • Do not use high-pressure washers that can bend fins.
  • Step 3 – Check fan speed:
    • Restore power and observe the outdoor fan.
    • If it runs slowly or intermittently, the motor or control may be failing.
  • Step 4 – Technician assistance: If F5 persists after cleaning and ensuring airflow, a technician should check system pressures, fan control, and compressor current draw.