H1
Hisense
Defrost Mode / Heating Delay Indication
Indoor unit displays H1 and heating does not start immediately; indoor fan may stop.
Advertisements
Possible Causes
Outdoor unit in defrost cycle, Low outdoor temperature causing frequent defrost, Control logic delaying indoor fan to prevent cold draft, Frost buildup on outdoor coil
How to Fix / Troubleshooting
Note: H1 on many Hisense heat pump models is an informational code indicating defrost or heating delay, not a fault.
- Step 1 – Wait for defrost to complete:
- Allow 5–15 minutes for the outdoor unit to complete defrost.
- The indoor fan may stop to avoid blowing cold air.
- Step 2 – Check outdoor unit:
- Ensure the outdoor coil is not buried in snow or ice.
- Clear snow from around the unit to improve airflow.
- Step 3 – Monitor frequency:
- If H1 appears very frequently and heating is poor, a technician should check defrost sensor operation and refrigerant charge.
Advertisements
Repair Difficulty
Very Easy
1/5
Advertisements