P3
Hisense
Low Temperature Protection / Anti-Freeze for Portable Unit
Portable Hisense air conditioner displays P3 and stops or runs at reduced capacity.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Room temperature too low for cooling mode, Blocked air filter or evaporator coil, Low refrigerant charge, Faulty evaporator sensor
How to Fix / Troubleshooting
Safety first: Unplug the unit before cleaning filters or coils.
- Step 1 – Check room temperature:
- Ensure the room is within the operating range (typically above 17–18°C for cooling).
- Step 2 – Clean filters:
- Remove and wash the air filters, then dry completely.
- Step 3 – Improve airflow:
- Ensure intake and exhaust vents are not blocked.
- Check that the exhaust hose is not excessively long or kinked.
- Step 4 – Allow thawing:
- If ice is visible on the evaporator, leave the unit off until all ice melts.
- Step 5 – Technician service: If P3 persists in normal conditions, a technician should check refrigerant charge and the evaporator sensor.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Portable AC Evaporator Temperature Sensor