F8
Hitachi Indoor Heat Exchanger Overcool / Freeze Protection

Unit stops with F8, sometimes after long continuous operation

Advertisements

Possible Causes

Very low indoor load with low fan speed, Dirty filters causing localized freezing, Faulty evaporator thermistor, Incorrect refrigerant charge

How to Fix / Troubleshooting

Safety first: Turn OFF the unit and allow any ice on the indoor coil to melt.

Steps:

  • Clean filters: Ensure filters are clean and properly installed.
  • Increase fan speed: Use a higher fan speed setting to improve airflow.
  • Adjust set temperature: Raise the cooling setpoint a few degrees to reduce overcooling.
  • Check for blocked vents: Ensure supply and return air paths are not blocked.

If F8 recurs frequently: The evaporator sensor or refrigerant charge may be incorrect; professional service is recommended.