Reduced Cooling Capacity / Poor Heat Exchange
Air conditioner runs but does not cool the room effectively; air from the outlet is only slightly cool.
Advertisements
Possible Causes
Dirty air filter, Clogged evaporator coil, Blocked condenser coil or exhaust, Failing compressor, Low refrigerant charge
How to Fix / Troubleshooting
Safety: Unplug the unit before cleaning coils or filters.
Steps:
- Clean filters: Remove and wash the intake filters with mild soap and water. Dry completely before reinstalling.
- Clean evaporator coil: Access the front coil and gently brush or vacuum dust from the fins. Use a non-rinse coil cleaner approved for aluminum fins if heavily soiled.
- Clean condenser / exhaust: For portable units, ensure the exhaust hose is straight, short, and not blocked. For window units, clean the outdoor coil with a soft brush and low-pressure water (power off, avoid soaking electrical parts).
- Check room size and heat load: Verify that the unit's BTU rating matches the room size and that doors/windows are closed and sun/heat sources minimized.
- Professional check: If airflow is good and coils are clean but cooling is still weak, have a technician check refrigerant charge and compressor performance.
Advertisements
Repair Difficulty
Easy
2/5