H6
Honeywell
Indoor Fan Motor Fault
Honeywell split or window AC shows H6 and indoor fan does not run.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed indoor fan motor, Seized blower wheel, Faulty fan capacitor (if used), Defective indoor PCB fan driver
How to Fix / Troubleshooting
Safety: Turn off power at the breaker or unplug the unit. Moving fan blades can cause injury.
Steps:
- Check for obstructions: Remove the front cover and inspect the blower wheel for foreign objects or heavy dust buildup. Clean and remove obstructions.
- Spin test: Gently spin the blower by hand. If it is stiff or seized, the motor bearings may be failing and the motor should be replaced.
- Electrical test: If you are comfortable and qualified, test the fan motor windings and capacitor (if present). Replace the capacitor if it is out of tolerance.
- Replace motor: If the motor is open, shorted, or seized, install a new Honeywell indoor fan motor assembly.
- PCB check: If a new motor does not run and H6 persists, the indoor control board may be defective and require replacement.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Indoor Fan Motor
Check Price on Amazon
We may earn a commission from links on this page.