HI
Honeywell
High Temperature Indication / Sensor Reading Above Range
Honeywell AC displays HI instead of a temperature and may run continuously.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Room temperature above measurement range, Room sensor open circuit, Sensor disconnected, Control board sensor input fault
How to Fix / Troubleshooting
Steps:
- Check ambient temperature: If the room is extremely hot (above the unit's rated range), HI may be normal. Improve ventilation and reduce heat sources.
- Inspect sensor: Remove the front cover and verify the room sensor is connected and not broken.
- Test sensor: Measure resistance; an open circuit will cause HI. Replace the sensor if open or physically damaged.
- Control board: If a new sensor does not resolve HI, the main PCB may be faulty and require replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Room Temperature Sensor