P1
Honeywell Bottom Tray Full / Condensate Tank High Level

Honeywell portable AC shows P1 and stops cooling; unit may beep.

Advertisements

Possible Causes

Full bottom condensate tray, Blocked internal drain path, Stuck float switch, Kinked continuous drain hose

How to Fix / Troubleshooting

Safety: Turn off and unplug the unit before draining water.

Steps:

  • Drain the bottom tray: Move the unit to a location where water spillage is acceptable. Place a shallow pan under the lower drain plug, remove the cap, and allow all water to drain. Reinstall the cap securely.
  • Check continuous drain (if used): Ensure the drain hose is not kinked, elevated above the drain outlet, or blocked. Flush the hose with water.
  • Inspect float switch: If P1 returns immediately, remove the rear panel and inspect the float mechanism in the bottom tray. Clean any slime or debris and verify free movement.
  • Test operation: Reassemble, plug in, and run the unit. If P1 no longer appears, the issue was likely a full tray or stuck float.
  • Replace float switch: If the float switch does not change state when moved, replace it with a compatible Honeywell float switch assembly.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Condensate Float Switch
Check Price on Amazon