Short Cycling / Improper Control
Unit frequently turns on and off (short cycling) without reaching the set temperature.
Advertisements
Possible Causes
Oversized unit for room, Thermistor located in poor airflow, Dirty filter causing rapid temperature swings, Control board logic issue
How to Fix / Troubleshooting
Steps:
- Check filter and airflow: Clean filters and ensure vents are not blocked. Good airflow stabilizes temperature sensing.
- Thermistor placement: Verify that the room sensor is not directly in the cold air stream from the outlet. If it is, gently reposition it closer to the return air path.
- Set reasonable temperature: Avoid setting the temperature extremely low; use a moderate setpoint to reduce cycling.
- Room size: If the unit is significantly oversized for the room, some cycling is unavoidable. Consider using a lower fan speed or relocating the unit.
- Control board: Persistent erratic cycling may indicate a faulty control board, which may need replacement.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Room Temperature Sensor
Check Price on Amazon