F2
Hotpoint Evaporator Temperature Sensor Out of Range

F2 is displayed; unit may shut down or fail to start cooling.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open/shorted evaporator thermistor, Sensor not in proper contact with coil, Damaged harness

How to Fix / Troubleshooting

Safety: Disconnect power before servicing.

Steps:

  • Access evaporator sensor: Remove front grille and filter to reach the evaporator coil and attached sensor.
  • Verify placement: Ensure the sensor is clipped firmly to the coil tubing or fins as designed.
  • Inspect and test: Check wiring for damage, test resistance, and compare to ambient sensor if similar type.
  • Replace if needed: Install a new Hotpoint evaporator thermistor and secure wiring.

After repair: Reassemble, restore power, and confirm F2 is cleared.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Evaporator Thermistor
Check Price on Amazon

We may earn a commission from links on this page.