P2
Hotpoint
High Condensate Level in Cooling Mode (Secondary Protection)
Portable unit displays P2 and may stop cooling; fan may continue to run.
Advertisements
Possible Causes
Restricted condensate drain path, Unit not level causing poor drainage, Faulty water level sensor
How to Fix / Troubleshooting
Safety: Unplug the unit before tilting or draining.
Steps:
- Level the unit: Ensure the portable AC is on a flat, level surface. Adjust casters or supports if necessary.
- Drain water: As with P1, open the designated drain port and empty the internal tank.
- Inspect internal drain: If accessible, check the internal drain channels and tubing for algae, slime, or debris. Clean with warm water and a mild detergent.
- Check sensor: Verify the water level sensor or float switch moves freely and is not obstructed.
Test: After draining and cleaning, restore power and confirm P2 is cleared.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Condensate Float Switch / Water Level Sensor
Check Price on Amazon