Insignia
Relay Chatter / Start Circuit Problem
Clicking or buzzing noise from the control area when the compressor should start, but compressor does not run.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Weak compressor run capacitor, Failing compressor relay on main PCB, Low supply voltage, Loose wiring to compressor
How to Fix / Troubleshooting
Safety first: Unplug the unit and discharge the capacitor before handling.
Steps:
- 1. Verify voltage: Ensure the outlet provides stable voltage within the specified range. Avoid using long extension cords.
- 2. Inspect capacitor: Access the electrical compartment and check the capacitor for bulging or leaks. Replace with the correct Insignia-rated capacitor if suspect.
- 3. Check compressor wiring: Confirm all connections at the compressor terminals are tight and not burned.
- 4. Board inspection: If the relay is chattering (rapid clicking), the main PCB may be failing. Replace the control board if visual damage is present or if a new capacitor does not resolve the issue.
- 5. Professional help: Persistent buzzing with no compressor start may indicate a locked compressor, requiring professional evaluation.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Main Control Board
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements