Insignia Relay Chatter / Start Circuit Problem

Clicking or buzzing noise from the control area when the compressor should start, but compressor does not run.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Weak compressor run capacitor, Failing compressor relay on main PCB, Low supply voltage, Loose wiring to compressor

How to Fix / Troubleshooting

Safety first: Unplug the unit and discharge the capacitor before handling.

Steps:

  • 1. Verify voltage: Ensure the outlet provides stable voltage within the specified range. Avoid using long extension cords.
  • 2. Inspect capacitor: Access the electrical compartment and check the capacitor for bulging or leaks. Replace with the correct Insignia-rated capacitor if suspect.
  • 3. Check compressor wiring: Confirm all connections at the compressor terminals are tight and not burned.
  • 4. Board inspection: If the relay is chattering (rapid clicking), the main PCB may be failing. Replace the control board if visual damage is present or if a new capacitor does not resolve the issue.
  • 5. Professional help: Persistent buzzing with no compressor start may indicate a locked compressor, requiring professional evaluation.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control Board
Check Price on Amazon

We may earn a commission from links on this page.