E4
Insignia Defrost / Frost Protection Sensor Fault or Evaporator Overfreeze Protection

Display shows E4; unit may shut down to protect itself, often after running for some time in cooling mode.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective frost/evaporator sensor, Sensor not in proper position on coil, Restricted airflow causing coil to freeze, Main PCB misreading sensor input

How to Fix / Troubleshooting

Safety first: Disconnect power before opening the front panel. Water and ice may be present around the coil.

Steps to address E4:

  • 1. Thaw the unit: Turn the unit off and allow any ice on the evaporator coil to melt completely. Place towels under the unit to catch drips.
  • 2. Clean air filter and grille: Remove and wash the air filter with mild soap and water. Ensure the front grille and air intake are not blocked by dust or objects.
  • 3. Inspect evaporator coil: With the front cover removed, check for heavy dirt buildup on the coil. If dirty, gently clean with a soft brush or coil cleaner, avoiding bending fins.
  • 4. Locate frost sensor: Many Insignia models use the same evaporator thermistor for frost protection. Confirm it is firmly attached to the coil in the correct location (usually mid-coil). Reattach if loose.
  • 5. Check fan operation: Power the unit briefly (with covers in place) and verify the indoor fan runs at all selected speeds. Poor airflow can cause freezing and trigger E4.
  • 6. Replace sensor if faulty: If the sensor tests open/shorted or E4 appears immediately on startup, replace the evaporator/frost sensor with the correct Insignia part.
  • 7. Persistent E4: If airflow is good, coil is clean, and sensor is new, the main PCB may be misinterpreting sensor data. Board replacement or professional diagnosis is recommended.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Evaporator/Frost Sensor
Check Price on Amazon