F2
Insignia
Outdoor / Condenser Temperature Sensor Error (Alternate Code)
F2 displayed; unit may shut down or run erratically, especially in very cold or hot conditions.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Open or shorted outdoor thermistor, Sensor dislodged from condenser coil, Wiring harness damage near outdoor section, Main PCB sensor input failure
How to Fix / Troubleshooting
Safety first: Unplug the unit and remove it from the window or housing carefully.
Steps to address F2:
- 1. Access condenser area: Remove the outer shell to expose the condenser coil and compressor compartment.
- 2. Locate outdoor sensor: Find the thermistor clipped to the condenser coil or near the outdoor air intake.
- 3. Check attachment: Ensure the sensor is firmly clipped to the coil and not hanging loose. Reattach if necessary.
- 4. Inspect wiring: Look for damage from vibration or rubbing against metal. Repair or replace damaged harness sections.
- 5. Replace sensor if faulty: If resistance tests open/shorted, install a new Insignia outdoor temperature sensor.
- 6. If F2 persists: A persistent F2 with a good sensor indicates a likely main PCB fault; replacement is recommended.