H3
Insignia
Compressor Overload Protection / Overheat
H3 displayed; unit may shut down compressor while fan continues to run.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked condenser airflow, Failed condenser fan motor, High ambient temperature and dirty coil, Failing compressor drawing excessive current
How to Fix / Troubleshooting
Safety first: Unplug the unit. Components in the compressor compartment can be extremely hot.
Steps to address H3:
- 1. Improve ventilation: Ensure the rear of the unit (or exhaust duct on portable models) is not obstructed. Move furniture or curtains away from vents.
- 2. Clean condenser coil: Remove the outer shell and clean the condenser fins thoroughly with a soft brush or vacuum.
- 3. Check condenser fan: Verify that the outdoor fan runs whenever the compressor is on. Replace the fan motor if it fails to start or is noisy and slow.
- 4. Inspect run capacitor: A weak capacitor can cause the compressor to overheat. Replace with the correct Insignia-specified capacitor if bulged or out of spec (advanced test).
- 5. Allow cool-down: Let the unit sit unplugged for at least 30 minutes to allow the compressor overload to reset, then test again.
- 6. Professional service: If H3 recurs quickly after cleaning and fan repair, the compressor may be failing internally and should be evaluated by a professional.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Condenser Fan Motor
Check Price on Amazon