P2
Insignia Upper Water Tray Full / High-Level Condensate Protection

Portable Insignia AC displays P2; unit may limit cooling or shut down intermittently.

Advertisements

Possible Causes

Blocked upper drain path, Kinked or improperly installed drain hose, Faulty upper float switch or sensor, Excessive condensate due to very high humidity

How to Fix / Troubleshooting

Safety first: Unplug the unit before draining or opening panels.

Steps to address P2:

  • 1. Drain both ports: Some Insignia portable models have upper and lower drain ports. Drain water from both to fully empty the system.
  • 2. Inspect drain hose (if used): Ensure any attached drain hose slopes downward continuously with no kinks or loops that can trap water.
  • 3. Clean internal tray: Remove the rear panel and locate the upper condensate tray. Clean out any buildup that could block the drain outlet.
  • 4. Check upper float/sensor: Verify that the upper float moves freely and that its wiring is intact. Replace the float switch if it remains in the “full” position even when the tray is empty.
  • 5. Test operation: Reassemble, restore power, and run the unit in COOL mode. If P2 reappears quickly, further inspection of the internal drain routing or sensor circuit on the main PCB may be required.