Insignia
Restricted Airflow / Fan Performance Issue
Unit blows air but airflow is very weak even on the highest fan speed.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Heavily clogged air filter, Dirty evaporator coil, Blower wheel packed with dust, Failing indoor fan motor or incorrect fan speed control from PCB
How to Fix / Troubleshooting
Safety first: Unplug the unit before cleaning or accessing the blower.
Steps to restore airflow:
- 1. Clean or replace filter: Remove and thoroughly clean the filter. Replace if it is damaged or does not come clean.
- 2. Clean evaporator coil: Remove the front cover and gently clean the coil fins with a soft brush or coil cleaner.
- 3. Inspect blower wheel: Check the indoor blower for dust buildup between the fins. Clean carefully with a brush and vacuum.
- 4. Check fan speeds: After cleaning, power the unit and cycle through fan speeds. If the motor does not change speed or is very slow, the motor or control board may be faulty.
- 5. Replace fan motor if needed: If the motor is weak or noisy, install a new Insignia indoor fan motor.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Indoor Blower Wheel
Check Price on Amazon
We may earn a commission from links on this page.