Insignia Locked or Overloaded Compressor

Unit emits a loud humming noise from the compressor area but does not cool; compressor may be very hot to the touch.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Mechanical failure inside compressor, Failed run capacitor, High head pressure from blocked condenser, Low supply voltage

How to Fix / Troubleshooting

Safety first: Unplug the unit. The compressor can be extremely hot; do not touch it directly.

Steps:

  • 1. Allow cool-down: Let the unit sit unplugged for at least 30–60 minutes to allow the compressor overload to reset.
  • 2. Check condenser airflow: Ensure the condenser coil is clean and the fan is operating properly.
  • 3. Inspect and replace capacitor: A weak capacitor can prevent the compressor from starting. Replace with the correct Insignia-rated capacitor if suspect.
  • 4. Test again: After cool-down and capacitor replacement, briefly run the unit. If the compressor still only hums and then clicks off, it is likely locked.
  • 5. Professional replacement: A locked compressor requires sealed system work and should be handled by a licensed HVAC technician.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Compressor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements