P0
Keeprite DC Bus Voltage Protection (Inverter Models)

Keeprite inverter-type air conditioner shows P0 and will not start or runs at reduced capacity.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect line voltage, Loose power connections, Faulty inverter module, Power surge damage

How to Fix / Troubleshooting

Safety first: Inverter systems contain high DC voltages. Turn off power at the breaker and disconnect and do not touch inverter components unless qualified.

  • Step 1 – Verify supply voltage: Have a qualified person measure line voltage at the disconnect to ensure it matches the unit nameplate (e.g., 208/230V).
  • Step 2 – Inspect connections: With power off, tighten all line and ground connections in the outdoor unit and disconnect.
  • Step 3 – Surge damage check: Look for burnt components on the inverter board. If present, the inverter module must be replaced.
  • Step 4 – Professional service: P0 faults generally require a Keeprite-trained technician to diagnose and replace the inverter or main control board.