Keeprite Insufficient Cooling Capacity

Keeprite air conditioner runs but does not cool well; supply air is only slightly cooler than room air.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Dirty indoor or outdoor coils, Low refrigerant charge, Oversized or undersized equipment, Duct leakage or poor duct design, Blower speed set too low

How to Fix / Troubleshooting

Safety first: Turn off power before removing panels or cleaning coils.

  • Step 1 – Filter and coil cleaning: Replace the air filter. Clean both indoor evaporator and outdoor condenser coils as described earlier.
  • Step 2 – Check airflow: Ensure all registers are open and ducts are not crushed or disconnected in accessible areas.
  • Step 3 – Temperature check: Measure temperature at a return grille and nearest supply grille. A typical split system should show about 16–22°F (9–12°C) drop under normal conditions.
  • Step 4 – Professional evaluation: If coils are clean and airflow is good but cooling is still weak, a technician should check refrigerant charge, duct static pressure, and system sizing.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Evaporator Coil
Check Price on Amazon

We may earn a commission from links on this page.