F2
Kelvinator Evaporator Coil Sensor Fault (Inverter Series)

Kelvinator inverter split AC shows F2 and may shut down during operation.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open or shorted evaporator thermistor, sensor not properly attached to coil, damaged harness, indoor PCB fault

How to Fix / Troubleshooting

Safety: Turn off power before working on the unit.

Steps:

  • Access coil: Remove front cover and filters to expose the evaporator coil.
  • Check sensor placement: Ensure the thermistor is clipped firmly to the coil tubing and not hanging loose.
  • Inspect wiring: Follow the sensor wires to the PCB, checking for damage or loose connectors.
  • Test and replace: Measure resistance; if out of spec, replace with a Kelvinator-compatible evaporator sensor.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Evaporator Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements