F9
Kelvinator Indoor Coil Frost Protection / Sensor Calibration Error

Kelvinator inverter split AC displays F9 and may not operate in certain modes.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect evaporator sensor reading, sensor not in correct position, firmware calibration issue, indoor PCB fault

How to Fix / Troubleshooting

Safety: Disconnect power before working on the indoor unit.

Steps:

  • Verify sensor placement: Ensure the evaporator thermistor is in the correct factory position on the coil and not relocated.
  • Check insulation: Some models require the sensor to be insulated from ambient air; restore any missing insulation sleeves.
  • Clean coil: A heavily iced or dirty coil can cause abnormal readings. Clean the coil with a suitable coil cleaner and allow it to thaw completely.
  • Replace sensor or PCB: If F9 persists, replace the evaporator sensor; if still unresolved, the indoor PCB may need replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Evaporator Temperature Sensor