H3
Kelvinator
Compressor Overload Protection
Kelvinator inverter split AC displays H3 and shuts down to protect the compressor.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
High discharge temperature, blocked condenser, low refrigerant causing overheating, faulty compressor cooling, incorrect voltage supply
How to Fix / Troubleshooting
Safety: Turn off power before servicing the outdoor unit.
User checks:
- Clean condenser coil: Remove dirt and debris from the outdoor coil to improve heat rejection.
- Ensure fan operation: Confirm the outdoor fan runs properly; replace if not.
- Check ventilation: Improve airflow around the outdoor unit and avoid enclosing it.
- Allow cooling: Let the unit rest for 30–60 minutes before restarting.
Technician tasks: Check refrigerant charge, compressor current, and discharge temperature. Persistent H3 usually requires professional diagnosis.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Compressor Assembly
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements