E9
Klarstein EEPROM / Memory Error on Main Control PCB

Display shows E9 and unit may not respond to mode changes or remote commands.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Corrupted EEPROM data, failed main control PCB, voltage surge damage, poor PCB grounding

How to Fix / Troubleshooting

Safety: Disconnect power before opening the control compartment.

Steps:

  • Power reset: Unplug the unit or switch off the breaker for at least 10–15 minutes to allow capacitors to discharge. Restore power and test.
  • Check supply voltage: Use a multimeter to verify that the mains voltage is within Klarstein’s specified range. Persistent over/under-voltage can corrupt memory.
  • Inspect PCB: Remove the control panel cover and visually inspect the main PCB for burn marks, corrosion, or insect damage. Clean light dust with dry compressed air.
  • Grounding: Ensure the earth/ground wire is securely connected to the chassis and PCB ground points.

If E9 remains, the main control PCB’s memory is likely damaged. The board must be replaced with a genuine Klarstein control PCB programmed for your model.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control PCB
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements